DAF Pretreatment Cuts Aquaculture Effluent SS from 620 to 28 mg/L

Background

The project is located in East China and belongs to a large-scale aquaculture base producing shrimp and freshwater fish, with roughly 300 mu (about 20 hectares) of pond surface plus a recirculation and effluent treatment area. As local discharge rules for aquaculture effluent tightened, the site's original "sedimentation tank + natural pond" approach could no longer keep up: the tank carried a permanent scum layer, algae bloomed in the pond, effluent suspended solids and total phosphorus repeatedly exceeded limits, and a regulatory inspection resulted in a deadline for rectification.

The client came to us with three clear requirements: effluent must consistently meet local aquaculture discharge standards; the footprint had to be small, since surrounding land was already in production; and operating cost had to stay controllable — aquaculture margins are thin, so power and chemical costs could not run away.

latest company case about DAF Pretreatment Cuts Aquaculture Effluent SS from 620 to 28 mg/L

Water quality and the core problem

On-site sampling (three composite samples, averaged):

Parameter Influent Target effluent
SS (mg/L) 620 ≤50
COD (mg/L) 780 ≤200
Oil & grease (mg/L) 46 ≤8
TP (mg/L) 12.6 ≤3
Ammonia nitrogen (mg/L) 58 ≤25

The pattern is typical: suspended solids formed from uneaten feed, manure, molted shells and algal debris are light, fine and slow to settle naturally. Large amounts of organic matter keep consuming oxygen and releasing nitrogen and phosphorus, overloading the downstream biological stage. Greasy material also attaches to pipes and aerators, causing clogging and efficiency loss.

We ran two bench tests. One used coagulation followed by sedimentation: after 60 minutes of settling, supernatant SS was still around 110 mg/L, and the scum was difficult to thicken. The other used coagulation plus dissolved air flotation: microbubbles lifted the flocs to the surface and separation was complete within 15 minutes, with clear effluent and noticeably lower sludge moisture than settled sludge. The conclusion was unambiguous — this is not a problem sedimentation can solve. The light solids have to be removed first.

latest company case about DAF Pretreatment Cuts Aquaculture Effluent SS from 620 to 28 mg/L

Process design

The final flow is: collection tank → lift pump → coagulation/flocculation (PAC + PAM) → DAF unit → intermediate tank → biological treatment → compliant discharge or reuse.

The core equipment is a Zhongqiao Enlightenment ZQ-DAF series dissolved air flotation unit:

Item Specification
Capacity 80 m³/h (peak 100 m³/h)
Air dissolution Partial recycle, pressurized
Recycle ratio 30% (adjustable 25–40%)
Dissolution pressure 0.4–0.5 MPa
Surface loading 6.5 m³/(m²·h)
Main material Coated carbon steel (304 SS wetted parts optional)
Skimming Chain-type skimmer, intermittent operation
Control PLC + HMI, dosing and skimming interlocked
Footprint approx. 8.0 m × 2.6 m (excluding dosing area)

Three design decisions mattered: a separate reaction zone and flotation zone, so flocs are not broken up before flotation; an adjustable recycle ratio, because pond effluent varies sharply between clearing season and normal operation, and tuning recycle ratio and dosage beats running fixed parameters; and separate scum collection into a sludge tank to avoid recirculating scum back into the system.

Performance

After six months of stable operation, third-party testing and online data gave the following averages:

Parameter Influent Effluent Removal
SS 620 mg/L 28 mg/L 95.5%
COD 780 mg/L 268 mg/L 65.6%
Oil & grease 46 mg/L 3.2 mg/L 93.0%
TP 12.6 mg/L 3.8 mg/L 69.8%

DAF is responsible for SS, oil and grease, and part of the COD and TP; the remaining COD is handled by the downstream biological stage. That is precisely the value of placing flotation ahead of biology — remove the visible load first, and let the biological system work with a lighter burden.

Operating cost: about 0.28 kWh/m³ of electricity and 0.11 CNY/m³ of chemicals, giving roughly 0.35 CNY/m³ in direct operating cost, excluding labor and depreciation. Compared with the original scheme, footprint fell by about 60%, and manual tank cleaning dropped from twice weekly to once monthly.

Client feedback and lessons

The site supervisor put it plainly: "We used to watch the settling tank constantly during clearing season. Now the unit runs itself — we mainly check when the scum bin needs to be hauled away." The base adopted the same model in its phase-two expansion.

Three lessons are worth recording: do not rely on sedimentation for aquaculture effluent — light, organic-rich, buoyant solids make it nearly ineffective, and converting to flotation costs less than repeated manual cleaning; recycle ratio and chemical dosage must be adjustable, because pond water quality swings seasonally and fixed parameters will fail at some point; and scum needs its own disposal route — low moisture and high organic content make it suitable as compost feedstock or for licensed disposal, never recirculated into the process.

latest company case about DAF Pretreatment Cuts Aquaculture Effluent SS from 620 to 28 mg/L