4-300 m³/d Carbon Steel Wastewater Treatment Plant with PLC Automatic Control for Integrated Sewage Treatment Equipment
4-300 m³/d Wastewater Treatment Plant
,Carbon Steel Integrated Sewage Treatment Equipment
,PLC Automatic Control Wastewater Treatment Plant
The A/O (anoxic/oxic) integrated wastewater treatment unit is the highest-volume product in domestic sewage treatment: short process train, low capital cost, simple operation, and effluent meeting Grade B discharge — sufficient for connections to municipal sewers, receiving waters or irrigation reuse.
The WSZ range from Zhongqiao Enlightenment covers 5 to 500 m³/day in carbon steel enclosures suitable for buried or above-ground installation, with hydrostatic testing and powered trial running completed before dispatch, leaving only foundations and pipe connections for the site.
For hotels, hospitals and residential estates — the three most common domestic sewage sources — selection differs not in the process but in three things: the flow profile, disinfection requirements and water quality characteristics.
The core problem of domestic sewage is organic matter plus nitrogen: COD and BOD need biological degradation, ammonia needs nitrification followed by denitrification. A/O separates the two jobs into two tanks — in the anoxic tank, denitrifiers use the organic carbon in the influent to reduce nitrate in the returned nitrified liquor to nitrogen gas; in the aerobic tank, organics are degraded and ammonia is nitrified.
Pre-denitrification makes full use of the influent carbon, gives a higher total nitrogen removal rate than post-denitrification, and eliminates the cost of an external carbon source.
The trade-off against MBR is equally clear: effluent is settled rather than membrane-filtered, suspended solids sit around 20 mg/L, and the water is not directly reusable for toilet flushing; in exchange there are no membranes, no cleaning chemicals, no replacement budget every five to seven years, and lower specific energy.
Where discharge goes to a sewer, a receiving water body or irrigation, Grade B already complies and membrane investment would be wasted; only reuse or discharge to sensitive waters justifies upgrading to A/O plus MBR.

| Stage | Main equipment | Function |
| Pre-treatment | Screen, equalization tank, lifting pumps | Traps debris; balances flow and quality |
| Anoxic tank | Submersible mixer, return inlet | Denitrification; consumes returned nitrate |
| Aerobic tank | Microporous aeration, composite media, return pump | Organic degradation; nitrification |
| Clarifier | Inclined tube or vertical-flow settling, sludge handling | Solids separation; sludge return and wastage |
| Disinfection | Sodium hypochlorite dosing or UV | Effluent hygiene indicators |
| Control | PLC, level and DO instruments, remote module | Automatic operation and fault alarms |
Two design details decide actual performance. First, distribution: each compartment has its own distribution system to prevent short-circuiting, raising volume utilization to 89.8 percent, 15 to 20 percent above conventional arrangements.
Second, dual returns: mixed-liquor return and sludge return are separate systems with independently adjustable ratios, so influent swings do not force a compromise between nitrogen removal and biomass retention.

| Source | Flow profile | Quality profile | Configuration notes |
| Hotel | Fluctuates with occupancy; high holiday peaks | Higher detergents, fats and oils; larger phosphorus load | Larger equalization, grease trap up front, chemical P removal where needed |
| Hospital | Relatively flat all day; contains disinfectant residues | Disinfectant residuals and pathogens | Pre-disinfection on campus, longer septic retention, larger contact tank per code |
| Residential estate | Three daily peaks, low overnight | Uniform quality, strong flow swings | Equalization for peaks, variable-frequency blowers for savings |
The hospital case deserves expansion. Medical wastewater must pass pre-disinfection and a septic tank on campus before entering the unit — outside the equipment scope but decisive for selection, because residual chlorine from pre-disinfection inhibits the biological system: at high levels it kills activated sludge, so dechlorination at the inlet or a larger dilution equalization is normally required.
Radioisotope laboratory wastewater must be collected and treated separately and never mixed into the domestic line.
Hotels are dominated by the peak-to-trough ratio: occupancy from 30 to 100 percent can triple the flow, and an equalization tank sized for 4 to 6 hours of daily flow absorbs most of it, while variable-frequency blowers cut energy at low load.
Residential swings are regular — three peaks and one overnight trough — so the control programme can preset blower and return pump stages by time band without relying on live instrumentation.

| Parameter | Influent | Effluent (Grade B) | Note |
| COD (mg/L) | ≤500 | ≤60 | Covers conventional domestic sewage |
| BOD₅ (mg/L) | ≤350 | ≤20 | Aerobic retention 6 to 8 hours |
| Ammonia (mg/L) | ≤45 | ≤15 | Extend retention for winter 8 mg/L compliance |
| Suspended solids (mg/L) | ≤270 | ≤20 | Clarifier effluent; regular desludging is critical |
| Total phosphorus (mg/L) | ≤5 | ≤1 | Biological removal limited; chemical dosing where needed |
| Faecal coliforms | — | ≤500 per L | Compliant after disinfection |
The boundary of Grade B should be stated up front: this effluent suits municipal sewers, general receiving waters or agricultural irrigation, not direct reuse for flushing or landscaping. Where the local standard is Grade A or stricter, the process changes to A/O plus MBR or adds fibre disc filtration — same shell, higher footprint and energy.
Obtaining written limits from the local environmental authority before construction matters more than any technical optimisation.

| Model | Capacity (m³/d) | Dimensions (mm) | Operating weight (t) | Installed / running power (kW) | Cost per m³ (CNY) | Footprint (m²) |
| WSZ-0.5 | 10 | 2500×1500×2000 | 9.15 | 4.08 / 2.41 | 1.60 | 21 |
| WSZ-1 | 20 | 5000×1500×2000 | 17.50 | 4.08 / 2.41 | 0.92 | 26 |
| WSZ-3 | 70 | 7000×2500×2500 | 51.31 | 6.26 / 3.69 | 0.46 | 41 |
| WSZ-4 | 100 | 10000×2500×2500 | 72.98 | 6.26 / 3.69 | 0.44 | 52 |
| WSZ-10 | 250 | 24000×2500×2700 (two units) | 175.25 | 15.80 / 9.20 | 0.43 | 110 |
| WSZ-20 | 500 | 39000×3000×2700 (three units) | 349.61 | 21.70 / 12.70 | 0.29 | 193 |
Above 200 m³/day a single tank exceeds transport limits, so the range switches to parallel units, each with its own blower and return pump, rotating at low load. Parallel layout also simplifies expansion: add one group and the existing system keeps running. For hospital and hotel projects, sizing the enclosure to the planned ultimate flow while operating to the near-term flow is more flexible than one oversized unit.
Buried installation succeeds or fails in the civil interface.
Foundations are designed for operating weight plus cover load with flatness within 3 mm over a 2 m straightedge; high-groundwater sites need an anti-flotation check; after setting, the tank is filled to design level before symmetrical backfill so unilateral soil pressure cannot distort it; ports, vents and sampling points are brought to surface with rain and fall protection.
These conditions belong in the technical annex of the purchase contract, not in site negotiation.
Three operating practices matter most. First, desludging rhythm decides clarifier life — waste sludge once or twice a week, because excess sludge concentration carries solids into the effluent. Second, chlorine dosing follows online residual readings: too much harms the receiving water ecology, too little fails the hygiene indicator.
Third, plan for winter: extend retention or reduce loading before nitrification slows, rather than remedying afterwards. The series holds China Environmental Protection Product Certification (CCAEPIEP-2023-1218), and the company operates certified quality, environmental, occupational health and safety, and energy management systems, providing a direct basis for the technical file required in overseas acceptance.
Selecting an A/O unit reduces to three moves. Fix the discharge destination first — if Grade B complies, do not buy membranes. Then configure equalization, disinfection and phosphorus removal to the duty profile of the source: hotel, hospital or residence. Finally, size the enclosure to the ultimate flow and run it to the near-term flow.
The product's strength is not any single figure but the fact that design, fabrication, water testing and documentation all happen in the factory, and what the owner receives on site is a connect-and-run unit with complete paperwork, capable of long-term unmanned operation — for hotels, hospitals and estates without dedicated wastewater staff, that is usually the deciding argument.

Efficient and Stable Zhongqiao Box Integrated Sewage Treatment Equipment for domestic Wastewater treatment
Skid Mounted Integrated Containerized Sewage Treatment Plant Equipment MBR System For Municipal Industrial Use
Durability And Corrosion Resistance PP Material Sewage Water Treatment Plant Integrated