Dissolved Air Flotation (DAF) Machine: High-Efficiency Oil and SS Removal for Wastewater Treatment
Settling cannot remove everything. Wastewater carries a class of pollutants that will not sink by design — emulsified oils, light flocs and flocculent colloids whose density is close to or below that of water; gravity separation on them is either unacceptably slow or simply ineffective. Dissolved air flotation reverses the direction: it makes the pollutants float.
Microbubbles attach to suspended solids and carry them to the surface, where a skimmer removes them continuously. For oily, papermaking, tannery and dyeing wastewater, DAF is often the highest-efficiency stage in the whole train.
Zhongqiao Enlightenment's air flotation series covers the GW and YW patented models (patents ZL 202120168243.1 and ZL201620927225.6) plus a high-efficiency dissolved air flotation line, spanning from a few to 150 cubic metres per hour.

The physical sequence has four steps. First, dissolving: a gas-liquid mixing pump draws recycled water and, through a suction port, air at the same time; the high-speed shear of the pump impeller dissolves the air into the water — up to 30 percent gas content depending on pump specification.
Second, release: the saturated, even supersaturated, water stabilises in the dissolved air tank and is instantly depressurised by the release device, producing a dense cloud of 25 to 40 micrometre microbubbles — that size is the key to efficiency, because smaller bubbles mean more surface area and a higher attachment probability.
Third, attachment and rise: chemically flocculated wastewater enters the flotation section, mixes thoroughly with the bubbles, which attach to flocs and oil droplets and carry them to the surface.
Fourth, skimming: the scraper moves along the full liquid surface, pushing scum from inlet to outlet end, up inclined metal plates into the discharge trough; treated water leaves through the outlet pipe fitted with a level adjustment device for the scum zone.
This mechanism fixes DAF's two irreplaceable positions: it removes what settling cannot, so it sits upstream as pre-treatment; and aeration into the water has a marked effect on surfactants and odour, giving it a deodorising side duty. The catalogue also notes that it effectively addresses sludge bulking in biological systems — taking part of the separation duty off the clarifier keeps sludge loading steadier.
The GW model uses pump-internal pressure mixing, producing 25 to 40 micrometre bubbles while pumping, and eliminates the reflux pump, air compressor, jet generator and dissolved air tank entirely.
Its gas-liquid separation tank adjusts automatically, delivers stable performance, debugs in about a minute, and tolerates frequent start-stop cycles without re-commissioning — practical for non-continuous plants: lunch breaks, maintenance windows and holiday shutdowns need no parameter re-tuning.
The YW model is assembled from proven components: skimmer system on nylon chain, dissolved air system, oil-free silent air compressor, multistage centrifugal pump, control cabinet and ladder platform. Nylon chain skimming resists moisture corrosion; the oil-free compressor keeps lubricant out of the dissolved air water; the multistage pump holds stable pressure.
The result is a compact, simple, small-footprint unit with low operation and maintenance thresholds.


| Technology | Problem it solves |
| Tubular reactor | Thorough chemical mixing; saves chemicals, energy and space; intelligently adjusts pH |
| Shallow-tank principle with inclined tubes | Shorter retention, better settling, lower sludge handling cost |
| Inclined-tank high-pressure dissolution | High gas solubility without a large tank; suits high-oil, high-SS wastewater |
| Anti-clogging releaser | Adjustable pressure-relief valve plus air release pipe; handles varying water quality |
| Inlet-side scraping | Reverse-direction scraping over the full surface; efficient discharge, denser scum |
| Laminar flow field | Fully laminar internal flow; less disturbance, higher separation efficiency |
The logic behind all six is the same: DAF loses efficiency in four places — bubbles detaching under hydraulic disturbance, releaser clogging, overly wet scum driving downstream disposal costs, and uneven mixing in the reaction zone wasting chemicals.
The tubular reactor governs chemical use; the laminar field and inclined tubes govern separation; the anti-clogging releaser and inclined-tank dissolution govern bubble quality; inlet-side scraping governs scum density. Match the technologies to the dominant pollutant: high-oil wastewater favours inclined-tank dissolution, high-SS wastewater favours the releaser and skimming system.
| Wastewater type | Colour | CODcr | BOD₅ | SS |
| Alcohol wastewater | 30% | 30% | 30% | 77% |
| Dyeing wastewater | 40% | 30% | 30% | 70% |
| Chemical wastewater | 40% | 30% | — | — |
| Edible-oil wastewater | — | 30% | — | 85% |
| Papermaking wastewater | — | 30% | — | 85% |
| Leather tanning wastewater | — | 30% | — | 85% |
Note: catalogue reference data (marked "for reference only" in the source); actual removal varies with water quality and dosing. The pattern is instructive: removal of SS and colour is strong, dissolved COD only modest — consistent with the mechanism, since DAF separates suspended and emulsified pollutants and leaves dissolved organics to the biological stage.
Positioning DAF as pre-treatment rather than main treatment is what lets each stage do its own job.
| Model | Dimensions (mm) | Total power (kW) | Scraper power (kW) | Dissolved air tank | Dead weight (t) |
| YW-5 | 3460×1900×2100 | 4.47 | 0.37 | DN400×1000 | 1.8 |
| YW-10 | 4460×2000×2100 | 5.05 | 0.55 | DN400×1000 | 2.2 |
| YW-30 | 6960×2700×2300 | 6.75 | 0.55 | DN600×1880 | 3.6 |
| YW-50 | 9060×2950×2550 | 11.35 | 0.55 | DN600×1880 | 5.7 |
| YW-80 | 11860×3200×2850 | 16.50 | 1.10 | DN600×2100 | 9.2 |
| YW-100 | 14360×3200×2850 | 18.10 | 1.10 | DN800×2100 | 11.2 |
| YW-200 | 17360×3700×3100 | 32.20 | 2.20 | DN800×2100 | 13.4 |
The range runs from YW-3 to YW-200. One point to verify before publishing: the catalogue labels treatment capacity in m³/day, yet the same rows list dissolved air water volume in m³/h (YW-100 corresponds to 46 to 50 m³/h) — cross-checked, the capacity column is more likely an hourly figure; confirm the unit with the factory before quoting to avoid an order-of-magnitude error.
Configurations also include clear-water pump models (40-200A to 100-200A) and air compressor models (OTS series) staged by machine size.
In the process train, DAF typically sits after screening and equalization, ahead of biology: the equalization tank balances flow, the dosing system completes coagulation-flocculation (PAC and PAM doses set by jar tests), DAF performs the solids separation, and the effluent moves on to biological treatment or discharge.
Combined with Zhongqiao Enlightenment's integrated sewage treatment equipment, DAF as pre-treatment measurably lowers the biological stage's load and foam problems.
Three operating points matter. First, dosing is the other half of DAF performance: flotation only lifts flocs that chemistry has built, and jar tests beat experience-based dosing. Second, dissolution pressure and reflux ratio should follow water quality — raise reflux when influent strength rises, rather than leaning on chemicals alone.
Third, remove scum promptly: scum left on the surface degasses and sinks back into the water, so the scraper's rhythm must match scum production.
The selection sequence for buyers runs: water analysis to establish the form and concentration of suspended solids and oils; match models and technology combinations to the dominant pollutant; then size the unit to the flow. Done in that order, DAF's position and specification in the train settle themselves — it is among the most efficient pre-treatment devices available, provided it is allowed to do only what it does best.


Efficient and Stable Zhongqiao Box Integrated Sewage Treatment Equipment for domestic Wastewater treatment
Skid Mounted Integrated Containerized Sewage Treatment Plant Equipment MBR System For Municipal Industrial Use
Durability And Corrosion Resistance PP Material Sewage Water Treatment Plant Integrated