Oily wastewater is the least cooperative stream a treatment plant handles. Machining emulsions, grease-trap effluent, oilfield produced water and food-processing fats all share one trait: the pollutants sit at or below the density of water, and oil droplets a few microns across would take hours or days to rise on their own — conventional settling tanks simply cannot touch them.
The Integrated DAF System takes a different approach: coagulation reaction, microbubble separation, scum skimming and dissolved-air recirculation are all built into one skid. Influent is flocculated in a tubular reactor, enters the flotation zone where 25 to 40 micrometre microbubbles lift the flocs, a scraper removes the scum continuously, and the effluent moves on to the next stage.
Zhongqiao Enlightenment's flotation range runs from YW-3 to YW-200, with the GW and YW models protected by patents (ZL 202120168243.1, ZL201620927225.6). Each system is commissioned before shipment — install, connect water and power, and it runs.

Conventional DAF projects scatter the reaction tank, flotation basin, dissolved air vessel and recycle pump across a site, with heavy civil works, complex piping and long commissioning. The integrated DAF merges them into a single carbon-steel or stainless vessel. Zone one is the tubular reactor, where chemicals and raw water mix and flocculate inside the pipe — no separate reaction tank needed.
Zone two is the flotation separation zone, built on the shallow-tank principle with inclined tubes that dramatically shorten retention time. Zone three is the dissolved air system: inclined-tank high-pressure dissolution achieves gas content up to 30 percent in a compact vessel, with no bulky saturation tank.
Zone four is skimming and discharge — inlet-side reverse scraping covers the full surface and feeds the scum trough directly. The control cabinet sits at one end of the unit; level adjustment, dissolution pressure and scraping rhythm are all handled from one panel. For retrofit projects this means zero new civil construction: the day the unit arrives is the day commissioning starts.
The key to a small flotation tank is shallowness. Deeper basins lengthen the bubble's rise path, increase hydraulic disturbance and raise the chance of floc detachment; the shallow-tank principle goes the other way, keeping separation depth under two metres, with inclined tubes shortening the journey further.
Inclined-tank high-pressure dissolution serves compactness too: dissolved air water reaches up to 30 percent gas content without a traditional large saturation vessel. Combined, these technologies compress the footprint markedly compared with conventional layouts.
Take the YW-10 (roughly 10 m³/h capacity basis): overall dimensions are only 4460×2000×2100 mm — small enough for a workshop corner, compact enough to be skid-mounted and moved between sites. For space-tight plant retrofits, catering districts and small machining parks, this dimension decides whether the project happens at all.
| Wastewater type | Oil form | DAF role | Typical process combination |
| Machining emulsion | Emulsified + free oil | Oil and SS removal after demulsification and flocculation | DAF + biological + filtration |
| Catering / food-processing grease | Animal and vegetable fats | Grease and solids removal, protecting pumps and piping downstream | Grease trap + DAF + biological |
| Oilfield produced water | Dispersed + emulsified oil | Oil and SS reduction ahead of reinjection or discharge | DAF + filtration |
| Metal surface treatment | Emulsified oil + heavy-metal flocs | Flotation of metal flocs together with oil | DAF + polishing treatment |
| Dyeing / tannery wastewater | Auxiliary oils + colloids | Colour and SS removal, easing biological load | DAF + biological |
Selection starts with the oil form: free oil is recovered in a grease separator first, emulsified oil must be destabilized before flocculation, and flotation only handles pollutants that have already agglomerated into flocs.
Catalogue reference data show SS removal up to 85 percent for edible-oil wastewater with about 30 percent COD removal — consistent with the mechanism: DAF separates suspended and emulsified pollutants, while dissolved organics belong to the biological stage downstream.

| Model | Dimensions (mm) | Total power (kW) | Scraper power (kW) | Dissolved air tank | Dead weight (t) |
| YW-5 | 3460×1900×2100 | 4.47 | 0.37 | DN400×1000 | 1.8 |
| YW-10 | 4460×2000×2100 | 5.05 | 0.55 | DN400×1000 | 2.2 |
| YW-30 | 6960×2700×2300 | 6.75 | 0.55 | DN600×1880 | 3.6 |
| YW-50 | 9060×2950×2550 | 11.35 | 0.55 | DN600×1880 | 5.7 |
| YW-80 | 11860×3200×2850 | 16.50 | 1.10 | DN600×2100 | 9.2 |
| YW-100 | 14360×3200×2850 | 18.10 | 1.10 | DN800×2100 | 11.2 |
| YW-200 | 17360×3700×3100 | 32.20 | 2.20 | DN800×2100 | 13.4 |
Unit basis to verify with the factory before quoting: the catalogue labels capacity in m³/day, yet the same rows list dissolved air water flow in m³/h (YW-100 corresponds to 46 to 50 m³/h); cross-checked, the capacity column is more likely an hourly figure.
The GW model's differentiator is compressor-free operation: pump-internal pressure mixing produces the 25 to 40 micrometre bubbles directly, eliminating the recycle pump, air compressor, ejector and saturation tank, and tolerating frequent start-stop without re-commissioning — well suited to intermittently operating workshops.
First, dosing decides half the result. Flotation lifts flocs, and floc quality depends on the coagulant (PAC) and flocculant (PAM) ratio — jar tests beat rule-of-thumb dosing, and emulsion streams additionally need demulsification trials to fix the chemical route.
Second, let the recycle ratio follow the water quality: raising dissolved-air reflux when oil content climbs is more economical than simply overdosing chemicals, and inclined-tank high-pressure dissolution leaves room for that adjustment.
Third, remove scum promptly: scum left too long on the surface degasses and sinks back, so the scraping rhythm must match scum production — oily scum has low moisture and decent calorific value and should be collected for licensed disposal.
Combined with Zhongqiao Enlightenment's integrated sewage treatment equipment, DAF as the pre-treatment stage measurably lowers biological load and foam problems — once oily sewage has been "de-oiled" by flotation, the biological system can finally digest what remains, steadily.

Efficient and Stable Zhongqiao Box Integrated Sewage Treatment Equipment for domestic Wastewater treatment
Skid Mounted Integrated Containerized Sewage Treatment Plant Equipment MBR System For Municipal Industrial Use
Durability And Corrosion Resistance PP Material Sewage Water Treatment Plant Integrated