Automatic Dissolved Air Flotation Machine: PLC Control for Industrial Wastewater Clarification
In an industrial wastewater plant, the most expensive line item is often not the equipment but the people standing watch over it. Chemical, papermaking, tannery, dyeing and food-processing streams swing widely in flow and load, day and night.
Under manual operation, dissolved air pressure is read by eye, scraping is timed by hand and chemical dosing is guessed from experience — performance tracks the skill of whoever is on shift, and the night crew usually gets the worst of it.
The Automatic DAF Machine hands that stage to a PLC: level, dissolution pressure, scraping rhythm and dosing interlocks all run in closed loops, and operators only patrol and refill chemical tanks. Zhongqiao Enlightenment's flotation range spans YW-3 to YW-200, with the GW and YW models protected by patents (ZL 202120168243.1, ZL201620927225.6).
The control cabinet ships with PLC control as standard; no-load and loaded interlock tests are completed before dispatch, so the unit enters automatic operation as soon as water and power are connected on site.

Automation is not about having a screen — it is about giving every previously manual task a sensor and a logic. Loop one, level: the outlet pipe carries a level adjustment device whose sensor feeds the PLC continuously, so the thickness of the clear-water zone under the scum layer self-corrects without anyone walking over.
Loop two, dissolution pressure: a transmitter on the dissolved air tank watches pressure while the compressor and recycle pump start and stop within the set band; the GW model's gas-liquid separation tank adjusts on its own, delivering stable performance with minute-scale commissioning.
Loop three, scraping: the scraper runs on a timer or is triggered by scum level, so scum neither lingers long enough to degas and sink, nor is skimmed from an empty surface. Loop four, dosing: the tubular reactor intelligently adjusts pH, and dosing pumps interlock with influent flow and pH signals — replacing guess-based dosing with metered injection.
Loop five, protection: on water loss, overload or abnormal pressure the system alarms and shuts down by program, turning faults into notices instead of accidents.
PLC control changes how the plant is staffed, not just how it feels to operate. A conventional DAF station needs dedicated eyes on pressure, level and the scum hopper; the automatic machine compresses all three into one patrol per shift — and the patrol shifts from adjusting parameters to reading trends: is the pressure curve flat, is scum moisture normal, is there enough chemical in the tanks.
For non-continuous plants, frequent start-stop no longer requires re-commissioning: the GW model with pump-internal pressure mixing works at the push of a button after lunch breaks, maintenance windows and holiday shutdowns.
Industrial loads vary sharply between day and night; the PLC can hold two preset sets of reflux ratio and dosing parameters, one for the daytime peak and one for the night trough, keeping the unit in its best-efficiency band around the clock instead of running one parameter set all day.
| Wastewater type | Colour | CODcr | BOD₅ | SS |
| Alcohol wastewater | 30% | 30% | 30% | 77% |
| Dyeing wastewater | 40% | 30% | 30% | 70% |
| Chemical wastewater | 40% | 30% | — | — |
| Edible-oil wastewater | — | 30% | — | 85% |
| Papermaking wastewater | — | 30% | — | 85% |
| Leather tanning wastewater | — | 30% | — | 85% |
Note: catalogue reference data (marked "for reference only"); actual removal varies with water quality and dosing. The pattern is clear: removal of SS and colour is strong, dissolved COD only modest.
The correct role for industrial wastewater is pre-treatment ahead of the biological stage — solids and oil lifted first leave a steady biological load, which is also the mechanism behind the catalogue's note that DAF effectively addresses sludge bulking.
Automation matters here because it stabilises the pre-treatment output: load swings are absorbed by PLC-managed reflux and dosing, so the pollutant curve entering the biological stage stays flatter.
| Model | Dimensions (mm) | Total power (kW) | Scraper power (kW) | Dissolved air tank | Dead weight (t) |
| YW-5 | 3460×1900×2100 | 4.47 | 0.37 | DN400×1000 | 1.8 |
| YW-10 | 4460×2000×2100 | 5.05 | 0.55 | DN400×1000 | 2.2 |
| YW-30 | 6960×2700×2300 | 6.75 | 0.55 | DN600×1880 | 3.6 |
| YW-50 | 9060×2950×2550 | 11.35 | 0.55 | DN600×1880 | 5.7 |
| YW-80 | 11860×3200×2850 | 16.50 | 1.10 | DN600×2100 | 9.2 |
| YW-100 | 14360×3200×2850 | 18.10 | 1.10 | DN800×2100 | 11.2 |
| YW-200 | 17360×3700×3100 | 32.20 | 2.20 | DN800×2100 | 13.4 |
Unit basis to verify with the factory before quoting: the catalogue labels capacity in m³/day while the same rows list dissolved air water flow in m³/h (YW-100 corresponds to 46 to 50 m³/h); cross-checked, the capacity column is more likely an hourly figure.
The YW model comprises the skimmer system on nylon chain, dissolved air system, oil-free silent air compressor, multistage centrifugal pump, control cabinet and ladder platform — the control cabinet being the carrier of the PLC system. Clear-water pumps (40-200A to 100-200A) and compressors (OTS series) are staged by model size.
For the larger units (YW-80 and above) we recommend adding a remote data interface so level, pressure and dosing feed the plant's central control — the upgrade path to genuinely low-manning operation.

The selection sequence stays the same: water analysis to establish the form and concentration of suspended solids and oils; match models and technology combinations to the dominant pollutant; then size the unit to the flow.
For the automatic machine, confirm three more things: how influent flow is metered, since dosing interlocks depend on a reliable flow signal; where the online pH probe sits, with the tubular reactor outlet giving the most direct reading; and the alarm policy — which faults may trigger an automatic stop and which only notify, agreed item by item with the process engineers.
Two operating points remain. First, automation does not cancel jar tests: the PAC and PAM ratio still comes from bench trials; PLC-interlocked dosing enforces the quantity but does not decide it.
Second, dissolution pressure and reflux ratio still need to follow water quality: the PLC can hold segmented presets, but whether those presets are right comes from periodically reviewing operating data — pull the night-shift pressure curves against effluent results, and parameter tuning gains its evidence.
With both in place, the DAF clarifier runs stably on minimal staffing: the most efficient pre-treatment stage in the industrial train, with efficiency that no longer depends on who happens to be on shift.

Efficient and Stable Zhongqiao Box Integrated Sewage Treatment Equipment for domestic Wastewater treatment
Skid Mounted Integrated Containerized Sewage Treatment Plant Equipment MBR System For Municipal Industrial Use
Durability And Corrosion Resistance PP Material Sewage Water Treatment Plant Integrated